Items |
Technical parameters |
||
|
Model |
TPS110M-12K Ver. 3.0 |
TPS220M-12K Ver. 3.0 |
|
|
Cable length |
110M |
220M |
|
|
Ambient temperature |
-20~45℃ (working),-40~65℃ (storage) |
||
|
Relative humidity |
10~80%RH (working),5~90%RH (storage) |
||
|
Altitude |
≤3000m |
||
|
Ground power module |
Input voltage |
360-440Vac wide range input, three-phase five wires, 380Vac,frequency 50/60Hz |
|
|
Output voltage |
700~900Vdc adjustable |
||
|
Output power |
≤15.0KW (rated long-term output), ≤20.0KW (peak value ≤ 30s) |
||
|
Take-up and payoff speed |
0~2m/s, adjustable |
||
|
take-up and payoff tension |
0~25N, adjustable |
||
|
Interface |
Input LP32-5P, Output CNLINKO LP20-2P female aviation plug, Type-C wired communication, fiber optic FC port (optional) |
||
|
Button and switch |
AC switch, front lighting switch, backup battery switch |
||
|
Protection level |
IPx4 (Level 4 Waterproof grade actual tested) |
||
|
Backup battery for retract cable |
Nominal 14.8V, fully charged 16.8V, 51.8Wh, 3500mAh 116*84*25.2mm, 358±6g |
||
|
Size |
D560*W360*H480 ±0.5mm, excluding foot pads and external accessories |
||
|
Weight |
36.0 ±0.2kg, including 110m cable |
||
|
Cable |
Material |
Alloy lightweight high-temperature resistant aviation wire, composite fluoroplastic insulation layer, high modulus tensile aviation grade fiber woven layer |
|
|
Fiber optic communication |
The tethered cable is an optoelectronic composite cable containing tightly wrapped single-mode fiber with optional fiber optic communication. |
||
|
Current |
Rated 20A |
||
|
DC resistance |
1.8±0.2Ω, 100m@20℃loop |
||
|
Resistance Tensile strength |
≤150kg, resistant to repeated reaction and release times≤1000 |
||
|
Insulation strength |
≤3000Vdc, 1min, no breakdown |
||
|
Cable length |
Standard equipment 110m, optional 160m and 220m; Fiber optic with FC connector (optional). |
||
|
Outer diameter |
5.3±0.1mm |
||
|
Weight |
42.0±1g/m |
||
|
Air module |
Input voltage |
600~900Vdc wide range input |
|
|
Output voltage |
50.0/58.5Vdc±1%, constant voltage output |
||
|
Output power |
≤12.0KW (rated long-term output), ≤15.0KW (peak value ≮10s) |
||
|
Protection function |
Input overvoltage and undervoltage protection Output overvoltage, overcurrent, short circuit, and over temperature protection |
||
|
Isolation voltage |
3000V (Vin-Vout), 1min, leakage current ≤ 5mA, no breakdown, flashover, or corona phenomenon |
||
|
Installation method |
Reserved installation holes, fixed with screws |
||
|
Heat dissipation method |
External fan for active cooling, reserved air ducts for forced air cooling |
||
|
Interface |
Input LP20*1 male, output PDC28*1 |
||
|
Protection level |
IP54 actual tested |
||
|
Size |
260*180*66 ± 0.5mm, excluding mounting lugs |
||
|
Weight |
≤4000 ± 100g, excluding external connectors and cable |
||
|
Packing |
Size |
720×720×650±5mm (Aviation Hard Size) |
|
|
Net Weight |
40.0±0.5kg |
44.0±0.5kg |
|